What is Permanent Pressure Loss?

Symbol: PPLmbar, kPaFlow Measurement

Permanent pressure loss is the part of the DP across a flow element that is not recovered downstream and costs pumping energy.

Advertisement

Permanent Pressure Loss Explained

Pressure falls through a restriction and partly recovers further downstream. The unrecovered part is lost as heat and turbulence, and must be supplied by the pump or compressor.

Orifice plates lose most of their DP. Venturis recover most of it through their diverging section, which is why they are chosen for large lines and low pressure systems.

Permanent Pressure Loss Formula

Δϖ ≈ (1 − β1.9) × Δp
Δϖpermanent pressure loss for an orifice plate
βbeta ratio
Δpmeasured differential pressure
Example: At β = 0.6, Δϖ ≈ (1 − 0.379) × Δp ≈ 62 % of the DP.

Permanent Pressure Loss: Typical Values

Orifice plateabout 40 to 95 % of DP depending on β
Classical venturiabout 5 to 20 % of DP (ISO 5167-4)
Advertisement

Calculators for Permanent Pressure Loss

Frequently Asked Questions

What is Permanent Pressure Loss?

Permanent pressure loss is the part of the DP across a flow element that is not recovered downstream and costs pumping energy.

Why does pressure loss matter?

It costs energy continuously. On large water or gas lines the yearly energy cost of an orifice can exceed the price of a low loss meter.

Which meters have almost no loss?

Full bore meters such as magnetic and ultrasonic meters.