Free engineering calculators and unit convertersceo@instrumentationblog.in
IP, NEMA and Ex Rating Decoder · Free Tool

Ex Marking Decoder (ATEX and IECEx)

Paste the explosion protection marking from an instrument label or certificate to see what every part means and which hazardous area zones it may be used in.

ATEXIECExGas group and T classEPL and zones
Always check the certificate for special conditions of use (an X after the certificate number) and the permitted ambient range.
Allowed zonesZone 1, 2 (Gb)
Elements decoded6

Marking breakdown

ElementMeaning
II 2GATEX equipment group II (surface), category 2 gas: suitable for zone 1
ExExplosion protected equipment (IEC 60079 / EN 60079)
dbFlameproof enclosure (Ex d)
IICGas group IIC (hydrogen, acetylene); suitable for IIA and IIB too
T4Temperature class T4: maximum surface temperature 135 °C
GbEquipment protection level Gb: Gas, high protection
Advertisement

Anatomy of an Ex Marking

II 2G   Ex db   IIC   T4   Gb
ATEX group and category · protection type · gas group · temperature class · equipment protection level
ElementOptions
Protection typed flameproof, e increased safety, i intrinsic safety, m encapsulation, p pressurized, q powder, o liquid immersion, n type n, t dust enclosure
Gas groupIIA (propane) < IIB (ethylene) < IIC (hydrogen, acetylene); IIC covers all
Dust groupIIIA flyings < IIIB non conductive dust < IIIC conductive dust
Temperature classT1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °C
EPLGa/Gb/Gc for gas zones 0/1/2, Da/Db/Dc for dust zones 20/21/22

Worked example

Ex ia IIC T4 Ga: intrinsically safe with two fault tolerance, suitable for all gas groups and gases igniting above 135 °C, and allowed in zone 0, 1 and 2.

Key insight: square brackets, as in [Ex ia Ga] IIC, mark associated apparatus such as an isolator or barrier. It is installed in the safe area or with additional protection, while its field circuit may enter the hazardous zone.
Advertisement

Frequently Asked Questions

What does Ex db IIC T4 Gb mean?

A flameproof enclosure (db), for all gas groups including hydrogen (IIC), with a maximum surface temperature of 135 °C (T4), at equipment protection level Gb, which allows zone 1 and zone 2.

What is the difference between ATEX and IECEx?

ATEX is the European legal requirement with CE marking and categories; IECEx is an international certification scheme. Both use the same IEC 60079 protection concepts and markings.

What does the X at the end of a certificate number mean?

There are special conditions for safe use, such as cable entry or ambient limits, that must be read in the certificate.

You May Also Like

Learn more on the blog

Hazardous area classification zones

A practical, field focused guide on instrumentationblog.in that explains the theory behind this tool and how engineers apply it on real plants.

Read Full Article

More IP, NEMA and Ex Rating Decoder

More Instrumentation Tools