Level Measurement · Free Calculator

Sump Pump Cycle Time and Level Switch Calculator

Set the start and stop levels for a sump or wet well pump. The calculator finds the cycle time and starts per hour for your inflow, and the working volume needed to stay within the motor start limit.

Starts per hourWet wellStart and stop levelWorking volume
m²
starts/h
Cycle time at this inflow8 min
Starts per hour7.5
Pump run time per cycle4 min
Fill time per cycle4 min
Worst case starts per hour (inflow = ½ pump)7.5
Working volume needed for limit0.75 m³ (375 mm level band)
How this result was calculated
  1. Working volume V = A × Δh = 1 m³
  2. Cycle = V ÷ Qin + V ÷ (Qp − Qin) = 8 min
  3. Shortest cycle occurs at Qin = Qp ÷ 2: tmin = 4V ÷ Qp
  4. V needed = Qp × tmin ÷ 4 = 0.75 m³
Advertisement

Pump Cycle Formulas

Cycle time t = V ÷ Qin + V ÷ (Qp − Qin)
Shortest cycle (Qin = Qp/2): tmin = 4V ÷ Qp
Working volume V = Qp × tmin ÷ 4

V is the working volume between start and stop levels, Qp the pump capacity, Qin the inflow and tmin the minimum cycle time allowed by the motor (3600 ÷ maximum starts per hour). This is the standard method for sizing wet well working volume.

Worked example

A 30 m³/h pump in a 2 m² sump with a 0.5 m start to stop band and 15 m³/h inflow cycles every 8 min (7.5 starts per hour). To keep under 10 starts per hour at any inflow the working volume must be 0.75 m³, a 375 mm band.

Key insight: the worst case is not the highest inflow but an inflow of half the pump capacity, where the pump starts most often. Size the level switch band for that case.
Advertisement

Frequently Asked Questions

How many starts per hour can a motor take?

It depends on motor size and type; small submersible pumps often allow 10 to 15 starts per hour, large motors fewer. Check the motor or pump data.

Why is half the pump capacity the worst case?

Fill time and run time are then equal and their sum, the cycle time, is shortest.

How do duty and standby pumps change this?

Alternating two pumps halves the starts per pump. Many controllers alternate automatically.