1. In a DP flowmeter, if flow halves, the DP becomes:
2. The beta ratio of an orifice is:
3. Flow is generally turbulent when the Reynolds number is above about:
4. A magnetic flowmeter cannot measure:
5. A Coriolis meter directly measures:
6. A vortex meter works on the principle of:
7. Square root extraction for a DP flow loop should be done:
8. Typical upstream straight run for many flowmeters is about:
9. Q = A × v. If the pipe diameter doubles at the same flow, velocity becomes:
10. Nm³/h refers to gas volume at:
11. A turbine meter K factor is expressed in:
12. The main disadvantage of an orifice plate is:
13. Ultrasonic transit time meters work best on:
14. A low flow cut off is used on DP flow because:
15. 1 m³/h is approximately:
About this Quiz
15 multiple choice questions on flow measurement, the kind asked in instrumentation interviews, technician exams and plant training. Each answer comes with a short explanation, so the quiz works as a revision sheet too.
Show answer key
- One quarter: DP ∝ Q², so (0.5)² = 0.25.
- Bore ÷ pipe diameter: β = d ÷ D.
- 4000: Above about 4000 flow is turbulent; below 2300 it is laminar.
- Hydrocarbon oil: It needs a conductive liquid; oils are non conductive.
- Mass flow and density: Coriolis measures mass flow, and density from tube frequency.
- Von Kármán vortex shedding: The shedding frequency is proportional to velocity.
- In only one place: Applying it twice gives a large error.
- 10 D: About 10 D upstream and 5 D downstream is a common guide; check the meter data sheet.
- One quarter: Area ∝ D², so velocity falls to one quarter.
- Reference conditions (usually 0 °C, 1.01325 bar a): Normal cubic metres are at reference conditions.
- Pulses per unit volume: K factor = pulses per litre (or per m³).
- High permanent pressure loss and limited turndown: Orifices lose 40 to 90 % of the DP and have about 4:1 turndown per range.
- Clean liquids or gases: Transit time needs a clean acoustic path; Doppler suits fluids with particles.
- The square root amplifies noise near zero: Near zero, small DP noise becomes large flow noise.
- 4.40 US gpm: 1 m³/h = 4.403 US gpm (and 16.67 L/min).
Frequently Asked Questions
Is this quiz free?
Yes. No sign up is needed and you can retake it as often as you like.
Are the answers explained?
Yes. After you check your answers, each question shows the correct answer and a short explanation.
Where can I find more questions?
See the Interview Q&A section of instrumentationblog.in and the linked article below.
Learn more on the blog
100 flow measurement objective questions
A practical, field focused guide on instrumentationblog.in that explains the theory behind this tool and how engineers apply it on real plants.
Read Full Article