Process Analyser Quiz
Test yourself with 20 multiple choice questions. Check your answers to get a score and an explanation for every question.
Process Analyser Quiz: 20 Questions
Choose one answer for each question, then press Check answers. Explanations appear after checking.
1. A pH of 3 means hydrogen ion concentration of about:
2. Theoretical pH electrode slope at 25 °C is:
3. A pH electrode at pH 7 ideally gives:
4. pH calibration normally uses:
5. Which buffer absorbs CO₂ and drifts fastest?
6. pH temperature compensation corrects:
7. Conductivity equals conductance multiplied by:
8. Typical conductivity temperature coefficient is about:
9. 1000 µS/cm with factor 0.65 gives TDS of:
10. Ultrapure water conductivity at 25 °C is about:
11. Dissolved oxygen saturation in fresh water at 20 °C is about:
12. Turbidity per ISO 7027 is reported in:
13. ORP is measured with:
14. 50 ppm CO (M 28.01) at 25 °C is about:
15. Zirconia oxygen probes operate at about:
16. 3 % O₂ in flue gas means excess air of about:
17. Emission results are corrected to a reference O₂ to:
18. NDIR analysers cannot measure:
19. Sample lag time equals:
20. Water hardness is commonly expressed as:
About this Quiz
20 multiple choice questions on process analyser, the kind asked in instrumentation interviews, technician exams and plant training. Each answer comes with a short explanation, so the quiz works as a revision sheet too.
Show answer key
- 10⁻³ mol/L: pH = −log₁₀[H+]. Learn more: pH
- 59.16 mV/pH: Nernst slope 0.1984 × T. Learn more: Nernst Slope
- About 0 mV: The isopotential point is near pH 7. Learn more: Nernst Slope
- pH 7 and a buffer near process pH: Two point calibration sets offset and slope. Learn more: Buffer Solution
- pH 10: Alkaline buffers react with CO₂ from air. Learn more: Buffer Solution
- The electrode slope: Not the real change of sample pH with temperature. Learn more: pH Temperature Compensation
- The cell constant: κ = G × K. Learn more: Cell Constant
- 2 % per °C: Readings are referenced to 25 °C. Learn more: Conductivity Temperature Compensation
- 650 mg/L: TDS ≈ k × κ. Learn more: Total Dissolved Solids
- 0.055 µS/cm: Set by water self ionisation. Learn more: Conductivity
- 9.1 mg/L: It falls with temperature and salinity. Learn more: Dissolved Oxygen
- FNU: Infrared light at 90°; NTU with white light. Learn more: Turbidity
- A platinum or gold electrode and a reference: Reported in mV. Learn more: Oxidation Reduction Potential
- 57 mg/m³: 50 × 28.01 ÷ 24.45. Learn more: ppm to mg/m³ Conversion
- 600 °C or more: Zirconia conducts oxygen ions only when hot. Learn more: Zirconia Oxygen Sensor
- 17 %: O₂ ÷ (20.9 − O₂) × 100. Learn more: Excess Air
- Prevent dilution with air hiding emissions: C_ref = C × (20.9 − O₂ref) ÷ (20.9 − O₂meas). Learn more: Emission Oxygen Correction
- Oxygen: Oxygen does not absorb infrared. Learn more: NDIR Gas Analyser
- Line volume ÷ sample flow: Fast loops reduce it. Learn more: Sample Lag Time
- mg/L as CaCO₃: 2.497 Ca + 4.118 Mg. Learn more: Water Hardness
Frequently Asked Questions
Is this quiz free?
Yes. No sign up is needed and you can retake it as often as you like.
Are the answers explained?
Yes. After you check your answers, each question shows the correct answer and a short explanation.
Where can I find more questions?
See the Interview Q&A section of instrumentationblog.in and the linked article below.
Learn more on the blog
Electrical conductivity explained
A practical, field focused guide on instrumentationblog.in that explains the theory behind this tool and how engineers apply it on real plants.
Read Full Article