Pressure Measurement Quiz
Test yourself with 15 multiple choice questions. Check your answers to get a score and an explanation for every question.
Pressure Measurement Quiz: 15 Questions
Choose one answer for each question, then press Check answers. Explanations appear after checking.
1. Absolute pressure equals:
2. 1 bar is approximately:
3. A column of water 10 m high exerts about:
4. A Bourdon tube gauge on steam service should be fitted with:
5. For a gauge, the normal operating pressure should ideally be:
6. Accuracy class 1.0 on a 0 to 10 bar gauge allows an error of:
7. When removing a DP transmitter from service with a 3 valve manifold, the first step is:
8. Which sensor principle is used in most smart pressure transmitters?
9. A compound gauge measures:
10. Turndown of a transmitter with URL 250 mbar calibrated 0 to 50 mbar is:
11. Static pressure effect in a DP transmitter mainly causes:
12. A diaphragm seal is used mainly for:
13. 1 psi equals approximately:
14. A pressure switch trips at 8.2 bar rising and resets at 7.6 bar. The deadband is:
15. Liquid filled gauges are mainly used to:
About this Quiz
15 multiple choice questions on pressure measurement, the kind asked in instrumentation interviews, technician exams and plant training. Each answer comes with a short explanation, so the quiz works as a revision sheet too.
Show answer key
- Gauge pressure + atmospheric pressure: Pabs = Pgauge + Patm.
- 14.5 psi: 1 bar = 14.504 psi.
- 0.98 bar: P = ρgh = 1000 × 9.81 × 10 ≈ 98 kPa ≈ 0.98 bar.
- A siphon (pigtail): The siphon holds condensate that protects the Bourdon tube from live steam temperature.
- In the middle third of the scale: Working in the middle of the scale gives best accuracy and life.
- ± 0.1 bar: Class 1.0 means ± 1 % of span: 0.1 bar.
- Open the equaliser valve: Open the equaliser first so the sensor never sees one sided line pressure.
- Capacitive or piezoresistive: Capacitive and piezoresistive (silicon) sensors dominate smart transmitters.
- Both vacuum and positive pressure: A compound gauge reads below and above atmospheric pressure.
- 5:1: Turndown = URL ÷ span = 250 ÷ 50 = 5:1.
- A zero shift at line pressure: High line pressure on both sides can shift the zero; it is trimmed at line pressure.
- Corrosive, viscous, hot or clogging fluids: The seal isolates the instrument from the process fluid.
- 6.895 kPa: 1 psi = 6.895 kPa = 68.95 mbar.
- 0.6 bar: Deadband = trip − reset = 0.6 bar.
- Damp pointer vibration and pulsation: The fill fluid damps vibration and pulsation and lubricates the movement.
Frequently Asked Questions
Is this quiz free?
Yes. No sign up is needed and you can retake it as often as you like.
Are the answers explained?
Yes. After you check your answers, each question shows the correct answer and a short explanation.
Where can I find more questions?
See the Interview Q&A section of instrumentationblog.in and the linked article below.
Learn more on the blog
49 sensors and transducers questions and answers
A practical, field focused guide on instrumentationblog.in that explains the theory behind this tool and how engineers apply it on real plants.
Read Full Article