RTD and Thermocouple Quiz
Test yourself with 20 multiple choice questions. Check your answers to get a score and an explanation for every question.
RTD and Thermocouple Quiz: 20 Questions
Choose one answer for each question, then press Check answers. Explanations appear after checking.
1. Resistance of a Pt100 at 0 °C is:
2. Resistance of a Pt100 at 100 °C is about:
3. Standard alpha coefficient of IEC 60751 platinum is:
4. Which RTD connection fully removes lead resistance error?
5. IEC 60751 class A tolerance at 100 °C is:
6. Thermocouple voltage depends on:
7. Cold junction compensation adds:
8. Type K thermocouple output near room temperature is about:
9. Which thermocouple type is best below 0 °C?
10. Type K class 1 tolerance at 800 °C is:
11. Using copper cable from a thermocouple head to the DCS causes:
12. T90 of a first order sensor is about:
13. Thermowell failures are mostly caused by:
14. Thermowell design is checked with:
15. An NTC thermistor resistance:
16. A pyrometer reading a polished metal surface reads low because of:
17. Temperature class T4 limits surface temperature to:
18. Self heating error of an RTD increases with:
19. A temperature transmitter ranged 0 to 200 °C outputs at 75 °C:
20. 0 °C in kelvin is:
About this Quiz
20 multiple choice questions on rtd and thermocouple, the kind asked in instrumentation interviews, technician exams and plant training. Each answer comes with a short explanation, so the quiz works as a revision sheet too.
Show answer key
- 100 Ω: Pt100 means 100 Ω at 0 °C. Learn more: Pt100
- 138.5 Ω: R = 100 (1 + 0.39083 − 0.00578) = 138.51 Ω. Learn more: Pt100
- 0.00385: α = 0.00385 /°C. Learn more: Alpha Coefficient
- 4 wire: Voltage is sensed on leads carrying almost no current. Learn more: RTD Wiring (2, 3 and 4 Wire)
- ± 0.35 °C: ± (0.15 + 0.002 × 100) = ± 0.35 °C. Learn more: RTD Tolerance Class
- Temperature difference between hot and cold junctions: Seebeck voltage is generated along the gradient. Learn more: Thermocouple
- The table voltage at terminal temperature: Add voltages, not temperatures. Learn more: Cold Junction Compensation
- 41 µV/°C: Seebeck coefficient about 41 µV/°C. Learn more: Seebeck Effect
- Type T: Type T copper constantan suits low temperatures. Learn more: Thermocouple Types
- ± 3.2 °C: 0.004 × 800 = 3.2 °C, larger than 1.5 °C. Learn more: Thermocouple Tolerance Class
- Error, since the cold junction moves to the unmeasured head: Extension or compensating cable must continue to the CJC point. Learn more: Thermocouple Extension Cable
- 2.3 time constants: ln 10 ≈ 2.3. Learn more: Response Time
- Vortex induced vibration: Shedding near the natural frequency causes fatigue. Learn more: Wake Frequency
- ASME PTC 19.3 TW: It covers frequency limits and stresses. Learn more: Thermowell
- Falls as temperature rises: Negative temperature coefficient. Learn more: NTC Thermistor
- Low emissivity: Low emitting surfaces radiate less and reflect surroundings. Learn more: Emissivity
- 135 °C: T1 450, T2 300, T3 200, T4 135, T5 100, T6 85 °C. Learn more: Temperature Class
- Measuring current: Power = I² R. Learn more: RTD Self Heating
- 10 mA: 4 + 16 × 0.375 = 10 mA. Learn more: Temperature Transmitter
- 273.15 K: T(K) = t(°C) + 273.15. Learn more: Temperature Scales
Frequently Asked Questions
Is this quiz free?
Yes. No sign up is needed and you can retake it as often as you like.
Are the answers explained?
Yes. After you check your answers, each question shows the correct answer and a short explanation.
Where can I find more questions?
See the Interview Q&A section of instrumentationblog.in and the linked article below.
Learn more on the blog
100 temperature measurement objective questions
A practical, field focused guide on instrumentationblog.in that explains the theory behind this tool and how engineers apply it on real plants.
Read Full Article