Free engineering calculators and unit convertersceo@instrumentationblog.in
Piping · Free Excel and PDF

Pipe Inside Diameter and Flow Area Chart

Pipe inside diameter chart with the bore, internal flow area and contained volume per metre for Sch 40 and Sch 80 pipe.

Excel (.xlsx)Print ready PDF24 rowsFree, no sign up

Download

  • 24 rows of reference data
  • Print ready A4 PDF
  • How to Use sheet with steps
  • Basis and standard stated
  • Excel, Google Sheets and LibreOffice
  • Free, no sign up, no macros

Inside diameter, flow area and volume

NPSDNSch 40 ID mmSch 40 area cm²Sch 40 L/mSch 80 ID mmSch 80 area cm²Sch 80 L/m
1/866.840.370.0375.480.240.024
1/489.220.670.0677.660.460.046
3/81012.481.220.12210.700.900.090
1/21515.761.950.19513.841.500.150
3/42020.963.450.34518.882.800.280
12526.645.570.55724.304.640.464
1 1/43235.089.670.96732.508.300.830
1 1/24040.9413.161.31638.1411.421.142
25052.4821.632.16349.2219.031.903
2 1/26562.6830.863.08658.9827.322.732
38077.9247.694.76973.6642.614.261
3 1/29090.1263.796.37985.4457.335.733
4100102.2682.138.21397.1874.177.417
5125128.20129.0812.908122.24117.3611.736
6150154.08186.4618.646146.36168.2416.824
8200202.74322.8332.283193.70294.6829.468
10250254.46508.5450.854242.82463.0846.308
12300303.18721.9272.192288.84655.2565.525
14350333.34872.7087.270317.50791.7379.173
16400381.001140.09114.009363.521037.88103.788
18450428.461441.82144.182409.341316.01131.601
20500477.821793.16179.316455.621630.40163.040
22550501.841977.97197.797
24600575.042597.08259.708548.082359.27235.927
Advertisement

About this Table

Pipe inside diameter chart with the bore, internal flow area and contained volume per metre for Sch 40 and Sch 80 pipe.

Basis: Calculated from ASME B36.10M OD and wall: ID = OD − 2t, area = π ID² ÷ 4, volume per metre in litres = area in cm² ÷ 10.

How to use

  1. Use the ID for flow velocity and flowmeter sizing.
  2. Velocity in m/s = flow in m³/h ÷ (area in cm² × 0.36).
  3. Use L/m for line fill volumes and hydrotest water.

Notes

  • Flowmeter sizing should use the actual pipe ID, not the DN.

Related tools

Advertisement

Frequently Asked Questions

What is the ID of 4 inch Sch 40 pipe?

102.26 mm.

How do I get velocity from flow?

v (m/s) = Q (m³/h) ÷ (A (cm²) × 0.36).

Why is DN not the inside diameter?

DN is a size label. The real bore depends on OD and schedule.