Zones, EPL and equivalents

ZoneDefinitionPresenceEPLATEX categoryNEC equivalent
Zone 0Gas present continuously or for long periodsOver 1000 h per year (guide)Ga1GClass I Division 1
Zone 1Gas likely in normal operation10 to 1000 h per year (guide)Gb2GClass I Division 1
Zone 2Gas not likely; if present only brieflyUnder 10 h per year (guide)Gc3GClass I Division 2
Zone 20Dust cloud present continuouslyDa1DClass II Division 1
Zone 21Dust cloud likely in normal operationDb2DClass II Division 1
Zone 22Dust cloud not likely; if present only brieflyDc3DClass II Division 2
Advertisement

Gas and dust groups

GroupTypical substanceNEC groupMESG (gas)
IIAPropane, methane (mines are Group I)DOver 0.9 mm
IIBEthyleneC0.5 to 0.9 mm
IICHydrogen, acetyleneB (hydrogen), A (acetylene)Under 0.5 mm
IIIACombustible flyingsClass III
IIIBNon conductive dustClass II Group G
IIICConductive dustClass II Group E

About this Table

Hazardous area zone table linking IEC zones, equipment protection levels, ATEX categories and North American divisions, plus gas and dust groups.

Basis: IEC 60079 10 1 and 10 2 area classification, IEC 60079 0 equipment groups and EPL, ATEX 2014/34/EU categories, NEC Articles 500 and 505.

How to use

  1. Get the zone and group from the area classification drawing.
  2. Pick equipment with an EPL at least equal to the zone and a group at least equal to the gas.
  3. Check the temperature class as well.

Notes

  • Hour figures are common guidance, not part of the definitions.
  • IIC equipment may be used in IIB and IIA areas; not the reverse.

Related tools

Advertisement

Frequently Asked Questions

What is the difference between Zone 1 and Zone 2?

Zone 1 gas is likely in normal operation; Zone 2 only in abnormal conditions and briefly.

Can IIB equipment be used for hydrogen?

No. Hydrogen is IIC; IIB equipment is not suitable.

What EPL is needed for Zone 1?

Gb or better (Ga).