Differential Pressure Transmitter Data Sheet Template

A data sheet for differential pressure transmitters in flow, level and filter service, including static pressure rating, output function, remote seals, manifold and burnout direction.

Excel (.xlsx)Printable PDFFilled exampleFree, no sign up

Download

  • How to Use sheet with steps
  • Template sheet, blank and ready
  • Example sheet, filled in
  • Drop down lists for consistent entries
  • A4 portrait print setup
  • Works in Excel, Google Sheets and LibreOffice

Preview of the Filled Example

This is the Example sheet from the download, so you can see exactly how the completed differential pressure transmitter data sheet looks.

ProjectBoiler 3 upgrade
RevisionA
Date24 Oct 2026
Requisition noREQ INST 031

Specification

NoParameterValueUnit / notes
General
1Tag numberPDT 3105
2Service (flow, level or DP)Flow, orifice FE 3105
3Line or equipment6" Sch 40 feed line
4P&ID numberPID 300 01
5Hazardous areaZone 2, IIB T3
Process conditions
6FluidWater
7Static pressure (normal / maximum)10 / 16bar g
8Operating temperature (normal / maximum)60 / 90°C
9Design pressure / temperature25 / 120bar g / °C
10Differential range required0 to 250mbar

… and 24 more rows in the download.

Advertisement

About the Differential Pressure Transmitter Data Sheet

DP transmitters are the workhorse of flow and level measurement. Most problems come from the wrong static pressure rating, the wrong output function or missing seal and manifold details. A full data sheet removes those ambiguities before purchase.

How to fill in this template

  1. Enter the service and process conditions, including static pressure, which sets the transmitter body rating.
  2. Give the calibrated DP range from the flow element or level calculation, and the output function.
  3. Specify seals and capillaries for hot, viscous or corrosive service, and the manifold type.
  4. Choose the burnout direction so a failure drives the loop to the safe side.
  5. Issue with the requisition for vendor completion.

What the formulas do

  • No formulas: specification document laid out in sections like an ISA 20 style data sheet.

Related tools

Advertisement

Frequently Asked Questions

What is the difference between URL and calibrated range?

URL is the maximum DP the sensor can measure; the calibrated range is the part of it set to 4 to 20 mA for this service.

Square root in the transmitter or the DCS?

Either, but only in one place. State the choice on the data sheet and in the loop documents.

When are remote seals needed?

For hot, viscous, crystallising or corrosive fluids, or when the transmitter must be kept away from the process.